    摘要:

    为了解重庆段长江水作为热泵冷热源的概况,对重庆段长江水温的横断面变化和时间变化进行了实测分析,并对江水的水质和水位变化进行了分析,得到长江水温在整个横断面基本恒定,而江水的夏季月平均温度在22~25℃,冬季月平均温度在11~16℃,水温日变化幅度不超过0.5℃。是一种具有良好品质的稳定的冷热源。而长江水作为水源热泵的冷热源,主要解决的水质问题是泥沙和悬浮物,在三峡库区形成后水位变化可达到30 m,因此取水方式可考虑采用浮船取水方式。

    Abstract:

    Characteristics of smoke flow and fire spread in a patio space of a high-rise building were studied to investigate their influences on fire compartment and safety evacuation. Fire development model was established and fire scenarios were designed to simulate fire and smoke spread by CFD software numerically based on concepts of fire performance-based design in a high-rise building with double patio space, whose height are 74. 65 m and 55. 95 m, respectively. Simulation results show that in all fire scenarios, performance targets for safety evacuation for people in each floor was satisfied, if smoke was extracted naturally using the patio space. Hang walls mounted in corridors around the patio space prevent smoke flowing out smoothly, shorten the coming of the risk time and increase fire danger. Using chimney effect, it is preferred to adopt natural smoke exhaust method in a high rise building with patio space.

    参考文献
    相似文献
    引证文献
引用本文

王子云,付祥钊,王勇,仝庆贵.重庆市发展长江水源热泵的水源概况分析[J].土木与环境工程学报(中英文),2008,30(1):92-94104. WANG Zi-yun, FU Xiang-zhao, WANG Yong, TONG Qing-gui. Analysis of Yangtze River Water as a Potential Source for Developing a Water Source Heat Pump in Chongqing[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2008,30(1):92-94104.10.11835/j. issn.1674-4764.2008.01.023

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2007-05-21
  • 最后修改日期:2007-07-10
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码