超滤膜与不同处理工艺组合处理湖泊水的中试研究
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金(50638020);国家科技重大专项资助(2008ZX07422005)


Experimental Investigation of Ultrafiltration Membrane With Different Pretreatment technology for Lake Water
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为解决水厂现有净水工艺不能适应水源水质恶化的现状,采用国产超滤膜分别处理水厂的炭后水(工艺1)、滤后水(工艺2)和沉后水(工艺3),将超滤膜和水厂现有工艺结合,形成深度处理系统,研究超滤膜组合工艺的处理效能及超滤膜的过滤性能。研究表明:工艺1、工艺2和工艺3对CODMn的平均去除率分别为52.86%、39.62%和34.59%;DOC 的平均去除率分别为33.08%、23.60%和18.55%,UV254去除率分别为57.14%,39.66%和35.34%,藻类平均去除率分别为98.71%、97.84%和98.13%,3种工艺出水浊度均低于0.1 NTU,颗粒物粒径>2 μm的颗粒物控制20个/mL以下。工艺1运行45 d跨膜压差上升6.59%,产水率为98.02%;工艺2膜前加氯0.65 mg/L时,水力冲洗后跨膜压差可有效恢复,稳定运行10 d跨膜压差上升2.91%,产水率为97.63%;工艺3运行20 d跨膜压差上升13.52%,其产水率为97.01%。

    Abstract:

    In order to solve the problems that the exiting technologies do not adapt to the deterioration of the water quality in the water plant, the ultrafiltration was used to treat water respectively from ozonebiological activated carbon pool (process 1), sand filtration pool (process 2) and sedimentation tank (process 3) in the region of river network of southern China.It is found that the average DOC removal rate were 33.08%, 23.60%, and 18.55%, and the average alga removal are 98.71%, 97.84%, and 98.13% in the process 1, process2 and process3, respectively.The turbidity of the effluent is lower than 0.1 NTU, and the particles with their size bigger than 2 μm were lower than 20 per milliliter in all the three process.The transmembrane pressure increased by 6.59% and the water production rate of the UF membrane was 98.02% during 45 days pilot experiment in the process 1.When 0.65mg/L chlorine was added before ultrafiltration membrane, the transmembrane pressure was recovered effectively after hydraulic flush.And the transmembrane pressure increased by 2.91% and the water production rate of the UF membrane was 97.63% during 10 days pilot experiment in the process 2.The transmembrane pressure increased by 13.52% and the water production rate of the UF membrane was 97.01% during 20 days pilot experiment in the process 3.

    参考文献
    相似文献
    引证文献
引用本文

许航,陈卫,袁哲,陈杰,孙婧,韩志刚.超滤膜与不同处理工艺组合处理湖泊水的中试研究[J].土木与环境工程学报(中英文),2010,32(3):149-154. XU Hang, CHEN Wei, YUAN Zhe, CHEN Jie, SUN Jing, HanZhigang. Experimental Investigation of Ultrafiltration Membrane With Different Pretreatment technology for Lake Water[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2010,32(3):149-154.10.11835/j. issn.1674-4764.2010.03.026

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2009-12-25
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码