地铁站厅至站台楼梯口风速对火灾烟气运动的影响
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

上海科委基金资助项目(07d212022)


Analysis of Fire Smoke Movement with Different Air Velocity at the Stair head to the Hall of a Metro Station
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    地铁车站站台发生火灾,连接站厅与站台的楼梯口保持一定风速,可阻挡烟气向站厅蔓延并为人员疏散提供诱导气流。为研究楼梯口风速对车站火灾烟气运动的影响,试验对不同排烟模式下楼梯口风速进行测量,建立数值计算模型进行模拟。结果表明:火灾场景下楼梯口风速大于无火源场景下风速,因此常规楼梯口风速校核设计方法由于没考虑真实火灾情况下各种因素的复杂作用,需进一步改进;楼梯口附近起火,烟气易从挡烟垂壁溢出向站厅层蔓延,站台火灾时站厅层为送风状态,存在溢出烟气时站厅层烟浓度可增至大于站台层;站台公共区着火,增开隧道风机,能够增

    Abstract:

    When a fire happens at the subway platform, the downward ventilation at the staircase which connects the hall and platform can prevent smoke spreading into the hall and provides guiding air for evacuation people. To investigate the influence of the ventilation rate on the smoke movement, the air velocity at the staircase was measured under three ventilation modes. Numerical model was established to simulate the real fire scenario. It is shown that the downward air velocity under fire is greater than that without fire, and the traditional design procedure without considering complex factors interaction in real fire scenario should be improved; when fire is near the staircase, smoke easily spills from the smoke screen to the concourse. And smoke concentration of concourse is even higher than that of platform because the hall is under air supply mode; when the fire locates at the public area of the platform, turning on the tunnel fans can increase the downside flow at the staircase. However exceeding high flow can produce disturbance and destroy the smoke stratification, so more area will be filled with smoke. Therefore, reasonable smoke management scheme is as important as smoke exhausting system capability.

    参考文献
    相似文献
    引证文献
引用本文

闫淑霞,吴喜平.地铁站厅至站台楼梯口风速对火灾烟气运动的影响[J].土木与环境工程学报(中英文),2012,34(2):105-109. YAN Shu-xia, WU Xi-ping. Analysis of Fire Smoke Movement with Different Air Velocity at the Stair head to the Hall of a Metro Station[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2012,34(2):105-109.10.11835/j. issn.1674-4764.2012.02.017

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期: