遮阳金属百叶帘隔热性能实验研究
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Experiment Study on Thermal Insulation Performance of Metal Venetian Blind for Shading
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为研究遮阳金属百叶帘的隔热性能,本文通过模拟太阳光源的遮阳系数测试平台,对3 mm透明玻璃的得热系数、遮阳金属百叶帘的遮阳系数和不同状态下3 mm透明玻璃内外表面温度进行了测试与分析。分析结果表明:遮阳金属百叶帘关闭状态时能阻挡约87%的太阳辐射热量、水平状态时能阻挡约43%的太阳辐射热量,分析结果对遮阳金属百叶帘的实际隔热效果评价具有指导意义。

    Abstract:

    In order to study thermal insulation performance of the metal venetian blind for shading, the solar heat gain coefficient of 3mm clear glass、the shading coefficient of metal venetian blind for shading and inner-outside surface temperature of the 3mm clear glass under different conditions are tested and analyzed by the shading coefficient test platform that is based on solar-simulated light source. The results show that the metal venetian blind for shading holds about 87% of heat from the solar radiation when the metal venetian blind is closed, and the metal venetian blind for shading holds about 43% of heat from the solar radiation when the metal venetian blind is levelled. The analytical results have guiding-significance for thermal insulation evaluation of the metal venetian blind for shading.

    参考文献
    相似文献
    引证文献
引用本文

宋海罡,陈福霞.遮阳金属百叶帘隔热性能实验研究[J].土木与环境工程学报(中英文),2013,35(Z1):206-208. Song Haigang, Chen Fuxia. Experiment Study on Thermal Insulation Performance of Metal Venetian Blind for Shading[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2013,35(Z1):206-208.[doi]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2013-07-16
  • 出版日期:
文章二维码