下弦与撑杆新构型张弦梁结构的抗连续倒塌性能
作者:
作者单位:

长沙理工大学 桥梁与建筑绿色建造及维护湖南省重点实验室,长沙 410114

作者简介:

蒋友宝(1982- ),男,博士,教授,博士生导师,主要从事复杂结构分析与可靠度研究,E-mail:jiangybseu@163.com。
JIANG Youbao (1982- ), PhD, professor, doctorial supervisor, main research interest: analysis and reliability study of complex structures, E-mail: jiangybseu@163.com.

通讯作者:

中图分类号:

TU318

基金项目:

湖南省自然科学基金(2021JJ30716);长沙理工大学土木工程重点学科资助项目(18ZDXK01)


Progressive collapse resistance of beam string structure based on a new configuration of bottom chord and strut
Author:
Affiliation:

Hunan Provincial Key Laboratory of Green Construction and Maintenance of Bridges and Buildings, Changsha University of Science and Technology, Changsha 410114, P. R. China

Fund Project:

Natural Science Foundation of Hunan Province (No. 2021JJ30716); Civil Engineering Key Discipline Supported by Changsha University of Science and Technology (No. 18ZDXK01)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    由于传统张弦梁结构冗余度较低,下弦预拉索遭受意外作用断裂时易导致结构发生连续倒塌。通过改进传统张弦梁撑杆、下弦等杆件构型与连接形式,提出一种新型张弦梁结构。基于ANSYS/LS-DYNA程序平台,采用考虑初始状态的等效荷载瞬时卸载法,对具有不同撑杆交叉角度和交叉撑杆组数量的多个新型张弦梁结构模型进行抗连续倒塌分析。结果表明:合理设计后,任一段下弦失效时,交叉撑杆将代替失效处下弦为结构提供备用传力路径,新型张弦梁结构不会发生连续倒塌,但会导致下部撑杆内力骤增,下部撑杆设计需预留较大承载余量;撑杆交叉节点越靠近下弦,剩余结构空腹桁架作用越明显,承载能力越好;交叉撑杆组数越多,结构冗余度越高,新型张弦梁结构抗连续倒塌性能越优。

    Abstract:

    Due to the low redundancy of the traditional beam string structure, it is easy to cause a continuous collapse of a structure when the lower string prestay cable is broken by accident. A new type of beam string structure is proposed by improving the traditional tensioned beam spars, lower chords and the connection forms among members. Based on ANSYS/LS-DYNA program platform, some new beam string structure models with different spars crossover angles and spars numbers are analyzed for continuous collapse resistance by using the instantaneous unloading method of the equivalent load in the initial state. The results show that after reasonable design, the cross strut will replace the lower chord at the failure to provide a spare force transmission path for the structure when any section of the lower chord fails,and the new beam string structure will not progressive collapse, but the lower spar internal force will increase suddenly, the large bearing allowance shall be reserved for the design of the lower brace. And also show that the closer the brace cross node is to the bottom chord, the more obvious the effect of the vierendeel truss of the remaining structure and the better the load carrying capacity. The more cross brace groups, the higher the structural redundancy, and the better the progressive collapse resistance of the new beam string structure.

    参考文献
    相似文献
    引证文献
引用本文

蒋友宝,张梦华,周浩.下弦与撑杆新构型张弦梁结构的抗连续倒塌性能[J].土木与环境工程学报(中英文),2023,45(6):12-20. JIANG Youbao, ZHANG Menghua, ZHOU Hao. Progressive collapse resistance of beam string structure based on a new configuration of bottom chord and strut[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2023,45(6):12-20.10.11835/j. issn.2096-6717.2021.248

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-07-05
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-11-13
  • 出版日期: