冷弯薄壁型钢-结构防火一体板自攻螺钉连接性能试验研究
CSTR:
作者:
作者单位:

1.重庆大学 土木工程学院;山地城镇建设与新技术教育部重点试验室,重庆 400045;2.中国建筑西南设计研究院有限公司,成都 610041

作者简介:

熊刚(1976- ),男,博士,教授,主要从事钢结构研究,E-mail:xionggang76@126.com。
XIONG Gang (1976- ), PhD, professor, main research interest: steel structures, E-mail: xionggang76@126.com.

通讯作者:

石宇(通信作者),女,博士,教授,E-mail:shiyu7811@163.com。

中图分类号:

TU392.5

基金项目:

国家自然科学基金(52378132)


Experimental study on self-tapping screw connection performance of cold-formed thin-walled steel-structure fireproof integrated board
Author:
Affiliation:

1.School of Civil Engineering; Key Laboratory of Mountain Town Construction and New Technology of Ministry of Education, Chongqing University, Chongqing 400045, P. R. China;2.China Southwest Architecture Design and Research Institute Co., Ltd., Chengdu 610041, P. R. China

Fund Project:

National Natural Science Foundation of China (No. 52378132)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    开展冷弯薄壁型钢-结构防火一体板自攻螺钉连接抗剪性能试验研究,完成35个典型试件单调拉伸及低周往复加载试验,分析结构防火一体板厚度、螺钉直径、螺钉端距及加载角度等因素对其抗剪性能的影响。结果表明:不同加载角度及螺钉端距的试件呈现不同的破坏模式,主要包括板材端部撕裂破坏、板材孔壁承压破坏、板材被拉断破坏等,且破坏时试件的自攻螺钉存在不同程度的倾斜。对于试验端分别采用直径为4.8、5.5 mm螺钉的试件,试件的峰值荷载及延性系数与螺钉直径无明显相关性,弹性刚度随着螺钉直径增大而显著提升;随着螺钉端距由15 mm增大至25 mm,试件的弹性刚度无明显变化,而峰值荷载和延性系数提高了约35%;随着板厚由12 mm增大到20 mm,试件的峰值荷载提高了约40%,弹性刚度提高了约90%,延性系数降低了约30%;与加载角度为0°的试件的特征参数相比,加载角度为45°时,试件弹性刚度提高了约100%,峰值荷载及延性系数无明显差别;加载角度为90°时,试件弹性刚度及峰值荷载无明显差别,延性系数降低了约40%。

    Abstract:

    The shear test of self-tapping screw connection of cold-formed thin-walled steel-structure fireproof integrated board was carried out, and the monotonic tensile and low-cycle reciprocating loading tests of 35 typical specimens were completed, and the effects of structural fireproof integrated plate thickness, screw diameter, screw end distance and loading angle on their shear resistance were analyzed. The results show that the specimens with different loading angles and screw end distance showed different failure modes, mainly including tear failure at the end of the plate, pressure failure of the hole wall of the plate, and the failure of the plate to be pulled off, etc., and the self-tapping screws of the specimens had different degrees of inclination during the failure. For test pieces with screws with a diameter of 4.8 mm and 5.5 mm respectively at the test end,the peak load and ductility coefficient of the specimen have no obvious correlation with the screw diameter, and the elastic stiffness increases significantly with the increase of the screw diameter. With the increase of screw end distance from 15 mm to 25 mm, the elastic stiffness of the specimen did not change significantly, while the peak load and ductility coefficient increased by about 35%. With the increase of plate thickness from 12 mm to 20 mm, the peak load of the specimen is increased by about 40%, the elastic stiffness is increased by about 90%, and the ductility coefficient is reduced by about 30%. Compared with the specimen with a loading angle of 0°, when the loading angle is 45°, the elastic stiffness of the specimen is increased by about 100%, and the peak load and ductility coefficient do not change significantly. When the loading angle is 90°, the elastic stiffness and peak load of the specimen do not change significantly, and the ductility coefficient is reduced by about 40%.

    参考文献
    相似文献
    引证文献
引用本文

熊刚,折志伟,李环宇,石宇,刘宜丰,姜雪.冷弯薄壁型钢-结构防火一体板自攻螺钉连接性能试验研究[J].土木与环境工程学报(中英文),2024,46(3):134-143. XIONG Gang, SHE Zhiwei, LI Huanyu, SHI Yu, LIU Yifeng, JIANG Xue. Experimental study on self-tapping screw connection performance of cold-formed thin-walled steel-structure fireproof integrated board[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2024,46(3):134-143.10.11835/j. issn.2096-6717.2023.122