GFRP带肋筋黏结性能试验研究与简化本构模型
CSTR:
作者:
作者单位:

1.湖南大学,工程结构损伤诊断湖南省重点实验室,长沙 410082;2.湖南大学,土木工程学院,长沙 410082

作者简介:

张望喜(1971- ),男,博士,教授,主要从事结构基本理论、结构抗震与防连续倒塌性能研究,E-mail: wxizhang2000@hnu.edu.cn。
ZHANG Wangxi (1971- ), PhD, professor, main research interests: basic theory of structure, seismic analysis of reinforced concrete structures and anti progressive collapse performance research, E-mail: wxizhang2000@hnu.edu.cn.

通讯作者:

中图分类号:

TU528.572

基金项目:

国家自然科学基金(52078201)


Experimental study on the bonding performance of GFRP ribbed bars and simplified constitutive model
Author:
Affiliation:

1.Hunan Provincial Key Lab on Diagnosis for Engineering Structures, Hunan University, Changsha 410082, P. R. China;2.College of Civil Engineering, Hunan University, Changsha 410082, P. R. China

Fund Project:

National Natural Science Foundation of China (No. 52078201)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为研究GFRP(glass fiber reinforced polymer)带肋筋与混凝土之间的黏结性能并改进已有本构模型的实用性,制作14组试件进行梁端式试验,探讨混凝土强度、保护层厚度、配置箍筋以及GFRP带肋筋之间相互作用对黏结性能的影响。采用位移控制加载方式进行试验,测试并记录加载力、自由端滑移值和加载端滑移值,观察黏结界面的破坏情况,基于试验结果提出简化黏结-滑移本构模型的方法。结果表明:梁端式试验主要发生拔出破坏和劈裂破坏;黏结-滑移曲线的滑移值与肋间距有关,波峰间距基本与肋间距一致;混凝土强度和配置箍筋会影响黏结界面的破坏模式和损坏程度,进而影响黏结-滑移性能;增加保护层厚度对黏结-滑移性能的有利影响在一定范围内有效;二次拉拔试验结果表明,试件中GFRP带肋筋的黏结性能存在相互影响。黏结-滑移简化本构模型能较好地拟合试验数据,且进一步增强了实用性。

    Abstract:

    To investigate the bond performance between glass fiber reinforced polymer (GFRP) ribbed bars and concrete and improve the practicality of existing constitutive models, 14 sets of specimens were prepared for beam-end tests, which aimed to explore the influences of concrete strength, thickness of cover, stirrup configuration and the interaction between GFRP ribbed bars on the bond performance. The tests were conducted using displacement-controlled loading; loading force, free end slip value, and loading end slip value were recorded, the failure mode of the bond interface was observed, and a method for proposing a simplified bond-slip constitutive model was proposed based on the test results. The results showed that the beam-end tests mainly resulted in pull-out and splitting failures; the slip value of the bond-slip curve was related to the rib spacing, and the peak spacing was essentially consistent with the rib spacing; concrete strength and configuration of stirrups would affect the failure mode and damage degree of the bond interface, thereby affecting bond-slip performance; the increase in cover thickness had a beneficial effect on the bond-slip performance within a certain range; the results of the second pull-out test showed that there was a mutual influence on the bond performance of the GFRP ribbed bars in the specimens. The simplified bond-slip constitutive model can accurately fit the test data and further enhance the practicality of the constitutive model.

    参考文献
    相似文献
    引证文献
引用本文

张望喜,刘鑫,胡彬彬,向贞航,袁超,易伟建.GFRP带肋筋黏结性能试验研究与简化本构模型[J].土木与环境工程学报(中英文),2025,47(6):123-132. ZHANG Wangxi, LIU Xin, HU Binbin, XIANG Zhenhang, YUAN Chao, YI Weijian. Experimental study on the bonding performance of GFRP ribbed bars and simplified constitutive model[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2025,47(6):123-132.10.11835/j. issn.2096-6717.2023.113

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2023-04-23
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-12-17
  • 出版日期:
文章二维码