    摘要:

    紫外消毒技术因具有无须投加化学药剂、消毒广谱性、不产生消毒副产物等优势越来越受重视,但石英套管结垢引起的消毒效果难以保障成为限制紫外消毒技术发展的瓶颈。本研究在污水厂紫外线消毒渠中搭建中试实验装置,利用超声波抑制石英套管结垢,研究结果表明超声波可通过延长结垢诱导期来抑制垢的生成;以相对紫外线强度为考察对象,通过单因素实验确定超声波功率、清洗周期、超声时间合适的范围分别在500-1000W、0.5~1.0d、20~40min;对于使用时间为0年、0.5年、1年、3年和5年的石英套管,超声波均有很好的抑垢效果。为了进一步优化参数,采用 Box-Behnken设计法和响应面分析方法对主要因素加以优化,得到了响应面回归模型以及最优解。结果表明,超声波技术抑垢清垢的优化工艺参数为超声波功率P=965.057W,清洗周期T=0.540d,超声时间t=34.263min,预测相对紫外线强度最大值为1.011。通过统计学检验,模型具有良好的拟合性,在优化工艺条件下得到的相对紫外线强度预测值与试验值接近,误差为0.89%。

    Abstract:

    Ultraviolet disinfection technology has attracted more and more attention due to its advantages of no need to add chemicals, broad-spectrum disinfection, and no disinfection by-products. However, it is difficult to guarantee the disinfection effect caused by the fouling of quartz sleeves, which has become a bottleneck restricting the development of ultraviolet disinfection technology. In this study, a pilot test device was set up in the ultraviolet disinfection channel of the sewage plant, and ultrasonic waves were used to inhibit the fouling of quartz sleeves. Single factor experiments have determined that the appropriate ranges of ultrasonic power, cleaning cycle, and ultrasonic time are 500~1000W, 0.5~1.0d, and 20~40min respectively; Casing and ultrasonic both have good fouling inhibition effect. In order to further optimize the parameters, the Box-Behnken design method and the response surface analysis method were used to optimize the main factors, and the response surface regression model and the optimal solution were obtained. The results show that the optimized process parameters of ultrasonic technology for fouling inhibition and cleaning are ultrasonic power P=965.057W, cleaning cycle T=0.540d, ultrasonic time t=34.263min, and the maximum predicted relative ultraviolet intensity is 1.011. Through the statistical test, the model has a good fit, and the predicted value of the relative ultraviolet intensity obtained under the optimized process conditions is close to the experimental value, with an error of 0.89%.

    参考文献
    相似文献
    引证文献
引用本文
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2023-05-09
  • 最后修改日期:2023-07-17
  • 录用日期:2023-07-24
  • 在线发布日期:
  • 出版日期:
文章二维码