筒中筒结构宽扁梁预应力的建立
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TU317

基金项目:


Establishment of Pre-stress in Flat Beam of Tube-in-tube Structure
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    对混凝土筒中筒结构的楼盖预应力宽扁梁在不同施工阶段的预应力建立进行了分析和测试,并用有限元程序建立了对应阶段的结构分析模型,现场测试结果与有限元计算结果的对比分析,验证了原工程设计方法的可靠性,同时说明了在类似结构中预应力的建立以及预应力效应的产生是一个较为复杂的过程,应予以充分重视。

    Abstract:

    This paper introduces the analysis and test of prestressed flat beams in tube-in-tube concrete structures at different construction stages; moreover, the corresponding structural analysis models with FEA program are set up. Through the comparative analysis between the results of construction field test and that of calculation with FEA method, it proves the reliability of the primary design method; meanwhile, it also indicates that establishment of prestressing force and prestressed effects in similar structures is a complex procedure and should be noticed.

    参考文献
    相似文献
    引证文献
引用本文

秦士洪 陈刚 李唐宁 黄文 王林强.筒中筒结构宽扁梁预应力的建立[J].土木与环境工程学报(中英文),2005,27(1):56-61. QIN Shi-hong~,CHEN Gang~,LI Tang-ning~,HUANG Wen~,WANG Lin-qiang~. Establishment of Pre-stress in Flat Beam of Tube-in-tube Structure[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2005,27(1):56-61.10.11835/j. issn.1674-4764.2005.01.012

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:2004-10-20
  • 录用日期:
  • 在线发布日期:
  • 出版日期: