粘滞阻尼器在连体高层结构中的抗风减振效果
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

亚热带建筑科学国家重点实验室自主研究课题基金(C708086z)


Windinduced Response Analysis on a Connected Tall Building Structure with Viscous Damper
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    主要研究设置粘滞阻尼器的连体高层结构风振响应及风动力荷载作用下粘滞阻尼器对结构内力、变形、加速度及能量耗散的控制效果。根据连体高层结构刚性模型的风洞试验,得到风压系数时程数据。通过编制基于风洞试验的风荷载时程处理程序WINDHIST V2.0,可将风洞试验数据进行处理并导入有限元程序进行风振时程分析。对连体高层结构进行多工况风振时程分析,结果显示:设置粘滞阻尼器能减小连体结构内力及变形,内力的控制效果优于变形的控制效果。连体结构顶部加速度是由脉动风的动力效应引起,粘滞阻尼器能有效地控制结构顶部楼层加速度。

    Abstract:

    The control effects of a connected tall building structure with viscous damper in several respects were studied, such as internal force, deformation, acceleration and energy under dynamic wind load. Firstly, wind pressure timehistory data were obtained from the windtunnel test of the structure model, and then a wind load processing program WINDHIST V2.0 based on wind tunnel test was developed, by which wind pressure data processed and inputted into Finite Element Method(FEM) program. Thus windinduced vibration timehistory could be analysed under various working conditions. It was shown that both the internal force and deformation of the connected structure with viscous damper can be decreased, while the effect of the former was more obvious than the latter. The acceleration at the top of the connected structure caused by dynamic response of fluctuating wind can be controlled effectively by viscous damper.

    参考文献
    相似文献
    引证文献
引用本文

陈学伟,韩小雷,毛贵牛,季静.粘滞阻尼器在连体高层结构中的抗风减振效果[J].土木与环境工程学报(中英文),2009,31(5):74-80. CHEN Xuewei,HAN Xiaolei,MAO Guiniu, JI Jing. Windinduced Response Analysis on a Connected Tall Building Structure with Viscous Damper[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2009,31(5):74-80.10.11835/j. issn.1674-4764.2009.05.014

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2009-04-15
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期: