淋激式污水换热器换热管布置方向的选择
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金项目(51106190);重庆市建委科技资助项目(城科字2011第2-38号)


Selection of Direction Types of Tubes in Spray Type Sewage Heat Exchanger
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    淋激式污水源换热器以其较高的换热系数,方便运行维护及消耗较少能量等优点,近些年来,广泛应用于污水源热泵空调系统中。文中针对淋激式换热器换热管的布置方向选择进行了研究,通过运用数学工具和CFD模拟等手段,对2种不同布置方式的换热管的换热系数、液膜覆盖率、有效面积率等进行了研究。得出了在污水源热泵工程项目中,当机房面积比较狭小但高度空间充足的情况下,采用纵向布置换热管的淋激式换热器可以取得较好的效果。

    Abstract:

    In recent years, sewage source spray heat exchanger was widely used in sewage source heat pump systems with its higher heat transfer coefficient, easier operation and maintenance and less energy, etc. In this paper, we studied the direction arrangement of heat exchange tubes of spray heat exchanger. And the heat transfer coefficient, film coverage, effective area ratio has been studied through mathematical tools and CFD simulations and other means. The results showed that in the sewage-source heat pump project, when the engine room area is relatively small but highly space is sufficient, the vertical arrangement of spray heat exchanger tubes can obtain a good effect.

    参考文献
    相似文献
    引证文献
引用本文

纪鹏磊,林真国,蒋晏平,于祥雷.淋激式污水换热器换热管布置方向的选择[J].土木与环境工程学报(中英文),2013,35(Z1):195-197. Ji Penglei, Lin Zhenguo, Jiang Yanping, Yu Xianglei. Selection of Direction Types of Tubes in Spray Type Sewage Heat Exchanger[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2013,35(Z1):195-197.[doi]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2013-07-16
  • 出版日期: