再生水处理工艺CMF-S优化运行的中试研究
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家水体污染控制与治理科技重大专项(2009ZX07317-005-01)


Pilot Scale Test on Optimal Operation of CMF-S for Reclaimed Water Treatment
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    通过中试试验装置,结合夏季进水水质及高、中、低负荷3种运行工况对浸没式连续微滤(CMF-S)工艺运行参数进行优化研究。结果表明,CMF-S优化运行可减缓膜污染,提高运行效率,降低运行费用;利用运行数据建立跨膜压差TMP增长数学模型,确定主要影响因素,根据不同的工况条件,调控运行参数,实现微滤系统运行优化。

    Abstract:

    Combining with influent quality in summer and three loading conditions (low, medium and high), parameter optimazition of continuous micro-filtration (CMF-S) is studied through pilot-scale test. Results show that: 1) optimal operation of CMF-S can retard membrane fouling, improve operating efficiency and reduce the costs; 2) according to operation data of the CMF-S system, the mathematical model of △TMP growth can be obtained, by which we can identify the major influencing factors, and then regulate operating parameters under different conditions to achieve operation optimization of microfiltration system.

    参考文献
    相似文献
    引证文献
引用本文

章丽,田一梅,王睿,姜威,李育宏,李殿海.再生水处理工艺CMF-S优化运行的中试研究[J].土木与环境工程学报(中英文),2013,35(Z1):233-237. Zhang Li, Tian Yimei, Wang Rui, Jiang Wei, Li Yuhong, Li Dianhai. Pilot Scale Test on Optimal Operation of CMF-S for Reclaimed Water Treatment[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2013,35(Z1):233-237.[doi]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2013-07-16
  • 出版日期: