    摘要:

    以西安地区一栋典型办公建筑为例,运用EnergyPlus数值模拟软件研究了相变蓄热通风技术在过渡季节和炎热季节的应用情况。采用日累计降温幅度ΔT和降温潜力百分比J两个指标对其降温效果进行评价,分析了相变材料充分发挥相变潜能时室外干球温度的日气温特征,并基于ASHRAE 55热舒适模型评价了该技术对室内热环境的改善情况。结果表明:当室外干球温度最大值高于相变区间上限值3℃时,最低温度低于相变区间下限值3℃,且日平均温度处于相变区间范围内时,相变蓄热通风技术能够充分发挥相变蓄能作用;该技术在过渡季节的应用效果优于炎热季节,与夜间自然通风技术相比,该技术可使整个过渡季节室内空气温度降温幅度提高14%,室内操作温度满足ASHRAE 55标准的80%,可接受温度范围的小时数提高8%,而整个炎热季节室内空气温度降幅只提高5.6%,室内操作温度满足ASHRAE 55标准的80%,可接受温度范围的小时数仅提高1%。

    Abstract:

    In this paper, application potential of phase change heat storage coupled with night ventilation technology in transition and hot seasons were investigated using EnergyPlus, based on a typical office building in Xi'an. Two factors, daily cumulative cooling amplitude (ΔT) and percentage of cooling potential (J), were introduced to evaluate its cooling effect. The characteristics of outdoor dry-bulb temperature were examined when the technology realized its best cooling potential. The performance of the technology on improving the indoor thermal environment was also analyzed based on the standard ASHRAE 55 Adaptive Comfort Model. The results indicate that the technology can obtain excellent application effect when the maximum of outdoor dry-bulb temperature exceeds the upper limit of the phase change range 3℃ and its minimum is less than the lower limit of the phase change range 3℃ and its average is in the phase change range. The application effect of this technology in transition season is superior to that in hot season. Compared with night natural ventilation technology, the cooling amplitude in transition season and hot season by using the technology are increased by 14% and 5.6%, respectively, and the number of hours meets ASHRAE 55 standard 80% acceptability limit in transition and hot seasons are increased by 8% and 1%, respectively.

    参考文献
    相似文献
    引证文献
引用本文

刘江,杨柳,刘衍,侯立强,董宏,刘加平.西安办公建筑相变蓄热通风技术的季节适宜性研究[J].土木与环境工程学报(中英文),2019,41(1):150-159. Liu Jiang, Yang Liu, Liu Yan, Hou Liqiang, Dong Hong, Liu Jiaping. Study on seasonal suitability of phase change heat storage coupled with night ventilation in an office building in Xi'an[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2019,41(1):150-159.10.11835/j. issn.2096-6717.2019.019

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2018-07-19
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2019-04-04
  • 出版日期: