    与常规建筑不同,传染病医院的建设需严格控制其周边风环境与污染物浓度,而当前对其研究还极其匮乏。以长沙市某在建传染病医院为研究背景,利用大尺寸风洞10 m(宽)×3 m(高)对不同热力效应下医疗建筑风环境和污染物扩散进行了详细分析,探究了建筑布局和植被对病区气悬污染物扩散的影响。研究结论表明:在-0.23<Rb<0范围内,热力效应对风廓线影响主要集中在竖向分量,会较大程度影响流场分布的最大值;病区内污染物浓度大小主要受风速影响,当风速较大时,污染物浓度与当地热力效应呈正比关系。而在低风速时,污染物浓度与当地热力效应呈先增长后下降关系,且在Rb=-0.16时达到最大值;改变建筑布局是改善污染物浓度的有效办法,建筑朝向与主导风向一致时有利于污染物的扩散。植被增设在建筑回流区对污染物扩散具有一定促进作用,增设在通风廊道则不利于污染物扩散。

    Abstract:

    Compared with conventional buildings, Construction of infectious disease hospitals needs to strictly control the surrounding wind environment and pollutant concentration, but the current research is highly scarce.This paper takes an infectious disease hospital under construction in Changsha as the case study. The detailed analysis of wind environment and pollutant dispersion of medical buildings under different thermal effects was conducted by a 10 m (width)×3 m (height) wind tunnel test. In the process, building layout and vegetation are considered.The results show that in the range of -0.23<Rb<0, the wind profile influenced by the thermal effect is mainly concentrated in the vertical component. However, the thermal effect will greatly affect the maximum value of flow field distribution. The absolute values of pollutant concentration are affected primarily by wind speed. The pollutant concentration is positively proportional to the local thermal effect with high wind speeds. In contrast, at low wind speeds the pollutant concentration increases first and then decreases with the local thermal effect and reaches the maximum value when Rb=-0.16. Changing the layout of the building is an effective way to improve the concentration of pollutants. When the direction of the building is consistent with the prevailing wind direction, it is most conducive to the emission of pollutant. The addition of vegetation in the building reverse flow area can promote the diffusion of pollutants, while the greenery in the ventilation corridor will inhibit the spread of contaminants.

    参考文献
    相似文献
    引证文献
引用本文

汪阔,沈炼,韩艳,杨瑛,熊鹰,艾正涛.热力效应下传染病医院污染物浓度变化试验研究[J].土木与环境工程学报(中英文),2022,44(4):157-166. WANG Kuo, SHEN Lian, HAN Yan, YANG Ying, XIONG Ying, AI Zhengtao. Experimental study on airborne pollutant diffusion in infectious disease hospital under thermal effect[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2022,44(4):157-166.10.11835/j. issn.2096-6717.2021.159

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-04-30
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-05-06
  • 出版日期: