部分组合混凝土夹心板在温度作用下的力学行为
作者:
作者单位:

1.长沙理工大学 土木工程学院,长沙 410114;2.杭州交通投资集团有限公司,杭州 233290;3.中国电建集团贵阳勘测设计研究院有限公司,贵阳 550081;4.成都基准方中建筑设计有限公司,长沙 410000

作者简介:

梁建国(1963- ),男,教授,主要从事混凝土及砌体结构基本理论应用研究,E-mail: jgliang1963@163.com。
LIANG Jianguo (1963- ), professor, main research interests: application of basic theory of concrete and masonry structure, E-mail: jgliang1963@163.com.

通讯作者:

中图分类号:

TU311.4

基金项目:

湖南省教育厅优秀青年项目(18B141)


Mechanical behavior of partially concrete sandwich panels under temperature action
Author:
Affiliation:

1.College of Civil Engineering, Changsha University of Science and Technology, Changsha 410114, P. R. China;2.Hangzhou Communications Investment Group Co., Ltd, Hangzhou 233290, P. R. China;3.Power of China Guiyang Engineering Co., Ltd, Guiyang 550081, P. R. China;4.Chengdu Benchmark Fangzhong Architectural Design Co., Ltd., Changsha 410000, P. R. China

Fund Project:

Excellent Youth Project of Hunan Education Department (No. 18B141)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为了减轻作为建筑围护结构时混凝土夹心板因承受内外叶温度差作用而导致墙体开裂或破坏的情况,对其在温度作用下的内力和变形进行研究。将混凝土夹心板内外叶连接件匀质化,并假设内外叶混凝土只产生弯曲变形且内外叶的弯曲曲率不同,推导出混凝土夹心板的界面应力的解析解,从而得到夹心板内外叶最不利截面位置及其内力和挠度的理论计算公式,并利用有限元软件ABAQUS对理论公式进行验证。结果表明:理论公式与有限元分析结果吻合较好,且部分组合混凝土夹心板内外叶的跨中最不利截面内力与连接件刚度无关,跨中最大挠度随连接件刚度增大而增大,但增幅很小。

    Abstract:

    In order to reduce the crack or damage of the wall caused by the temperature difference between the inner and outer blades when the concrete sandwich slab is used as building envelope, the internal force and deformation of the concrete sandwich slab under the temperature action are studied. The internal and external blade connectors of concrete sandwich slab were homogenized, and the analytical solution of interfacial stress of concrete sandwich slab was deduced, assuming that the internal and external blade only produced bending deformation and the bending curvature of the internal and external blade were different. Thus, the theoretical calculation formula of the position of the most disadvantageous section of internal and external blade of concrete sandwich slab, as well as the internal force and deflection of internal and external blade were obtained, and the theoretical formulas were verified by the finite element software ABAQUS. The results show that the theoretical formula is in good agreement with the finite element analysis results, the internal forces of the most unfavorable section in mid-span of the inner and outer blades of partial composite concrete sandwich slabs have nothing to do with the stiffness of the connectors, and the maximum mid-span deflection increases with the stiffness of the connectors, but the increase is small.

    参考文献
    相似文献
    引证文献
引用本文

梁建国,雷灵芝,王吉波,李诚鄀,刘宇新.部分组合混凝土夹心板在温度作用下的力学行为[J].土木与环境工程学报(中英文),2023,45(5):173-180. LIANG Jianguo, LEI Lingzhi, WANG Jibo, LI Chengruo, LIU Yuxin. Mechanical behavior of partially concrete sandwich panels under temperature action[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2023,45(5):173-180.10.11835/j. issn.2096-6717.2021.177