COUPLING ANALYSIS METHOD FOR INTERACTION BETWEEN FOUNDATION WITH CAVERN AND FRAME STRUCTURE
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In this paper,the interaction between foundation withcavern and frame structure is studied by the coupling methods of BEMand FEM.On the interface between the foundation and structure,thecoupling analysis needs to satisfy both the condition of displacementcompatibility and force equilibrum.A calculating program for two-dim-ensional problem is worked out in the computer,SIEMENS 7570C.Twoengineering examples are calculated and the results are compared withthose obtained by the comventional simplified method and with the observedresults from the engieering structures.It indicates that it is necessaryfor the weak rock foundation with shallow cavern,in the buried depth,to take the interaction into account.