Experimental Research on Vertical Buried Tube Typeof Underground Exchanger for Ground-Source Heat Pump
Author:
Affiliation:

Clc Number:

TK172 TU831.4

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    This paper introduces the importance of developing the Ground-Source Heat pump and describes the prospects of it.with the method used abroad to acquire the temperature profiles within surrounding soil of the underground heat exchanger with buried tubes, in this paper the line heat source theory and thermal resistance network analysis method were used to set up the heat transfer model.The original temperature of the ground is determined by calculation and is compared with test results. Experiments of running single tube and running three series connection tubes are carried out on the built underground exchangers of vertical buried tube type.And the data which can provide reference for the Ground-Soure Heat pump technique are acquired.

    Reference
    Related
    Cited by
Get Citation

刘宪英 王勇.地源热泵地下垂直埋管换热器的试验研究[J].土木与环境工程学报(中英文),1999,21(5):21~26