Degradation of PCB Waste Stripping Liquid Using UV/Fenton
CSTR:
Author:
Affiliation:

Clc Number:

X703.1

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The study shows that there will be a good effect to degrade printed circuit board(PCB) waste stripping liquid using UV/Fenton homogeneous photochemical catalysis system.The removal rate of COD could reach 80% at the conditions with double dose of H_2O_2,1:20 mol ratio of Fe~(2+):H_2O_2 and 80min hydraulic retention time(HRT).In all influential factors the H_2O_2 dosing ratio is the most important by order,then follows the ratio of FeSO_4/H_2O_2,and at last the illumination time.