Abstract:The simulation analysis of temperature field under ideal condition can reflects the rule of true temperature field, but accidental factor during construction process will result in difference of the result. This paper studied the Baise RCC Dam with the distributed optical fiber technology and FEM technology, the numerical results were modified with the testing data and the contrastive curves can be obtained for the testing data,ideal simulation data and real -time simulation data. The results indicate that the modified real - time simulation can reflect the true temperature field ; it may serve as a guide for the temperature control.