Performance of Drainage Reuse as Waterscape Treated by Combinational Technique of Biologic Contact Oxidation and Constructed Wetland
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The high grade gray water was pretreated by biologic contact oxidation on load of 0.72 KgBOD5·m-3·d-1, and then posttreated by constructed wetland. On the basis of experiment, it was found that: Totle nitrogen (TN) was the restrictive index of the combinational technique. To meet the reclaimed water quality standard and reuse for waterscape, the peak hydraulic load of constructed wetland was 0.50 m·d-1 in summer (30~36 ℃), and 0.33 m·d-1 in winter (8~12 ℃). And the load ratio of the peak hydraulic under the summer and winter conditions was 3:2. With the experimental results and reclaimed water quantity requirements in different seasons of buildings, treatment scale can be determined.

    Reference
    Related
    Cited by
Get Citation

胡学斌,柴宏祥,彭述娟,龙腾锐.生物接触氧化-人工湿地组合工艺中水处理回用景观水体效能试验[J].土木与环境工程学报(中英文),2009,31(6):112~116