Abstract:Eight concrete beams reinforced with 500MPa steel bars and four reinforced with 400MPa ultrafine grain steel bars were tested under twopoint symmetrical concentrated static loading to observe the details of crack pattern development on these beams and investigate their cracking characteristics. It was shown that the cracking behavior of the beams with highstrength bars was essentially similar to that of common RC flexural members, whereas the computed crack widths using the formula adopted in the Code for Design of Concrete Structures GB 500102002 exceeded that of the experiment under the normal service. Furthermore, the formulas for crack spacing and crack width specified in GB 500102002 were evaluated through the experimental results and previous studies of sixtyseven concrete beams reinforced with highstrength bars. On the basis of the calculation model in GB 500102002, revised formulas for crack spacing and crack width were proposed. The values calculated by revised formulas were in good agreement with the test results.