    Abstract:

    Lighting and airconditioning energy consumption of stadium is very large. That how to use natural lighting and natural ventilation is the key pivot for stadium energy efficiency design. A variety of passive energy efficient measures were used in the Multifunctional stadium of Guangdong College of Pharmacy, such as lighting windows with vertical blinds in east and west facades, Openable windows on south and north facades, planting roof and etc. It was found that the abovementioned passive designs could 〖JP2〗increase natural illumination of competition venues, prevent the glare, raise wind speed in audience area, improve comfort level and decrease internal surface temperature of affiliated building and reduce heat radiation.

    Reference
    Related
    Cited by
Get Citation

张磊,孟庆林,李晋.体育馆建筑被动式节能技术实测与分析——以广东药学院体育馆为例[J].土木与环境工程学报(中英文),2010,32(1):101~106