Reaction Kinetics of Three Types of Constructed Wetland for Advanced Domestic Wastewater Treatment
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The removal efficiencies of different pollutants in subsurface flow constructed wetland (SSFW), surface flow constructed wetland (SFW) and combination flow constructed wetland(CFW) treating sewage plant effluent were comparatively analysed. The results were analyzed by using a reaction kinetics model. It is shown that COD, TN, TP are more effectively removed in SSFW than in other two types of wetland, and the kinetic constants are 0.29, 0.20, 0.28 m/d respectively. The SFW has higher removal rate on ammonia and the kinetic constant is 0.12 m/d. Temperature change greatly affects the kinetic constants of ammonia and total nitrogen removal reaction, whilst the influence on COD and TP are not significant. The pollutants removal efficiencies decrease greatly with the increase of hydraulic loading and areal loading. The increment of areal removal mass is reduced with the increase of areal loading in three types of wetland. It is strongly recommended that the constructed wetland be operated on low pollutants loading condition.

    Reference
    Related
    Cited by
Get Citation

付国楷,王敏,张智,周琪.人工湿地用于污水深度处理的反应动力学[J].土木与环境工程学报(中英文),2012,34(4):111~117

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: September 05,2012
  • Published:
Article QR Code