Bearing Capacity of Bar-Reinforced Concrete-Filled Square Steel Tubular Short Columns After Fire
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Based on the determined stress-strain relationship of steel and concrete after fire, a temperature field and mechanical model of bar-reinforced concrete-filled square steel tubular columns after fire was set up with using ABAQUS, and the model has been validated by testing results. Then this paper analyzed the side of section, bar ratio, fire duration time, steel ratio and material strength parameters on the bearing capacity of bar-reinforced concrete-filled square steel tubular columns after fire. It is found that fire duration time and side of section is the dominant factor. Lastly this paper puts forward a theoretical formula of bearing capacity of bar-reinforced concrete-filled square steel tubular columns after fire, for the post-disaster restoration and provides references for the reinforcement.

    Reference
    Related
    Cited by
Get Citation

张童,吕学涛.火灾后方钢管钢筋混凝土短柱承载力分析[J].土木与环境工程学报(中英文),2013,35(Z2):49~52

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: February 25,2014
  • Published:
Article QR Code