Experimental Analysis on Energy Dissipation Mechanism and Seismic Performance of Steel Truss Coupling Beam-Coupled Shear Wall Structure
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Pseudo-dynamic tests and low cyclic reversed loading tests on two-floor coupled shear wall planar structures were conducted, and one is arranged with two steel truss coupling beams, the other is arranged with a steel coupling beam and a RC coupling beam. The shear walls’ seismic response under different earthquake intensity was deliberated, Their failure mechanism, bearing capacity, hysteretic ductility, energy dissipation mechanism, and stiffness and strength degradation mechanism were analyzed as well. The results show that the shear wall with two steel truss coupling beams has reasonable stiffness distribution. Its energy dissipation mechanism, stiffness and strength degradation mechanism can fulfill the demands of coupled shear wall’s seismic design: under rare earthquake, it can maintain good bearing capacity and stiffness, and keep restraining the walls. Its seismic performance is superior to RC coupling beams-coupled shear wall system.

    Reference
    Related
    Cited by
Get Citation

林倩,邓志恒,黄莹,胡岳峰.钢桁架连梁-联肢剪力墙耗能机理及抗震性能试验研究[J].土木与环境工程学报(中英文),2014,36(1):16~24

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:June 15,2013
  • Revised:
  • Adopted:
  • Online: February 21,2014
  • Published:
Article QR Code