Model Test and Mechanical Behavior Analysis of Steel-concrete Joint of Hybrid Girder
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To study the bearing behavior, failure mode and mechanical behavior of different structural forms of steel-concrete joint of hybrid girder, based on the hybrid girder of Jiujiang Yangtze River Highway Bridge with 818-metre main 8pan, select a pressure-resistant shear-transferred steel-concrete joint, redesign a shear-transferred only joint for contrast, carry out two scale 1:2 model specimens bearing behavior experiment, measure the strain and relative slip of steel and concrete. The results show that:the bearing capacity of the pressure-resistant shear-transferred specimen is twice than the other;the bearing plate carries about 62.5% of the axial load, the force transmission of the bearing plate reduces the steel stress、steel-concrete relative slip and the force transmission ratio of connectors, makes the load transferred more effectively.

    Reference
    Related
    Cited by
Get Citation

江祥林,刘玉擎,孙璇.混合梁结合部受力机理模型试验研究[J].土木与环境工程学报(中英文),2014,36(6):48~53

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:May 25,2014
  • Revised:
  • Adopted:
  • Online: December 23,2014
  • Published:
Article QR Code