    Flowing dynamic characteristics and its temperature dynamic characteristics of a three-level sewage pipe network in Chongqing were analyzed. A mall's building whole year load was simulated. In the adverse condition of wastewater flow, the market construction peak discharge heat was compared with the sewage heat load, the balance between the most adverse flow and the building demand was found. Explored supply and demand matching method between urban sewage and city building load in flow adverse condition to take full advantage of the urban sewage cold and hot resources. the composite system was adeptcd to make up the most unfavorable flow time of sewage average heat load and the construction load difference; it also puts forward principle of load sharing and control strategy aimed at compound system.