Influence of T-type rib on flexural fatigue behavior of concrete composite slab with precast prestressed ribbed panel
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In order to investigate influence of T-type rib on flexural fatigue behavior of concrete composite slab with precast prestressed ribbed panel, experiment is conducted to study the concrete composite slab with precast prestressed T-type rib panel and cast-in-place slab. The factors influencing the fatigue failure pattern and fatigue damage, such as T-type rib and fatigue load parameter, are studied by fatigue tests. The dynamic deflection, strains of concrete and prestressed tendons, and residual deflection are measured. Stiffness degradation, strain distribution, crack distribution and residual bearing capacity are analyzed. Results show that composite slabs with precast prestressed T-type rib panel can achieve the same flexural fatigue behavior as cast-in-place slabs. Design formulas for normal section bending fatigue strength of concrete composite slab with precast prestressed ribbed panel are put forward with reference to the four assumptions of traditional prestressed concrete flexural member.

    Reference
    Related
    Cited by
Get Citation

黄海林,祝明桥,曾垂军,吕伟荣. T形板肋对预制带肋底板混凝土叠合板弯曲疲劳性能的影响[J].土木与环境工程学报(中英文),2016,38(2):11~20

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 30,2015
  • Revised:
  • Adopted:
  • Online: May 09,2016
  • Published:
Article QR Code