Heat conduction of fire protection for isolated rubber bearings under fire
CSTR:
Author:
Affiliation:

Clc Number:

TU352.12

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    This paper studies the heat conduction limit of fire protection for isolated rubber, and provides theoretical evidence and experimental data for fire protection. Based on one-dimensional unsteady heat conduction, formula under ISO834 standard fire is derived. According to the GB 9978.1-2008 fire test, three kinds of components, LNR500, LNR1500 support board fire protection, LNR500 support board with flexible fireproof material fire protection, are tested.Modeling and finite element thermal analysis are carried out via ABAQUS. The numerical analysis and fire test results verified the proposed theory. Based on the derivation and experimented data, when the temperature of the support surface reaches the critical temperature of 150℃, the table of the limit thermal conductivity of fireproofing board with different thickness can be referred in engineering applications.

    Reference
    Related
    Cited by
Get Citation

王岚,王立雄,詹旺宇,刘红波.火灾下隔震橡胶支座防火保护热传导研究[J].土木与环境工程学报(中英文),2019,41(3):96~103