Response surface optimization of high-efficiency treatment of dye wastewater with non-temperature plasma
CSTR:
Author:
Affiliation:

1.College of Life Sciences, Chongqing Normal University, Chongqing 401331, P. R. China;2.Beijing Mercury Environment Co., Ltd, Beijing 101501, P. R. China;3.The Second Construction Engineering Co., Ltd. of China Construction Third Bureau, Wuhan 430000, P. R. China

Clc Number:

X703.1

Fund Project:

National Key Research and Development Plan of China (No. 2017YFC0404703)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In recent decades, atmospheric-pressure plasma technology has been rapidly developed in the field of water treatment, and has a good application prospect, but it still remains a challenge to reduce operating energy consumption and improve processing efficiency for industrial applications. In this paper, a simple and industrially scalable prototype of plasma reactor based on dielectric barrier discharge (DBD) at atmospheric-pressure air condition is employed to the methylene blue(MB) simulated dye wastewater with complex structure and stable performance. The effects of discharge voltage, air volume, initial concentration, initial pH and initial conductivity on the treatment of methylene blue wastewater are studied. The contribution of ·OH in the treatment of methylene blue wastewater by dielectric barrier discharge reactor is quantitatively analyzed. The study further uses the Box-Behnken response surface method to find the optimal operating parameters of the system: initial pH4, discharge voltage 13 kV, initial concentration 100 mg/L. The results show that the device can effectively treat methylene blue wastewater. After 15 minutes of discharge under optimal conditions, the MB degradation rate was 95.39%, the energy efficiency was 14.87 g/kWh, the reaction rate constant was 0.202 6 min-1, and the reduction rate of the chemical oxygen demand (COD) value is 62.63%, the chromaticity change is also obvious, indicating that the device can be industrially applied to the treatment of organic dye wastewater.

    Reference
    Related
    Cited by
Get Citation

曹力,李德祥,邓亚宏,石益广,袁小兵,孙志国,付世建.基于响应面优化的常压等离子体技术处理模拟染料废水[J].土木与环境工程学报(中英文),2023,45(2):229~238

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 15,2021
  • Revised:
  • Adopted:
  • Online: March 20,2023
  • Published:
Article QR Code