Anchorage performance of nail head for GFRP bar soil nail support
CSTR:
Author:
Affiliation:

1.School of Civil and Transportation Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, P. R. China;2.Beijing Urban Construction Exploration & Surveying Design Research Institute Co., Ltd., Beijing 100176, P. R. China;3.Beijing Geotechnical Engineering Association, Beijing 100005, P. R. China

Clc Number:

TU433

Fund Project:

Beijing Municipal Natural Science Foundation-Key Project of Beijing Municipal Education Commission (No. KZ201810016021); Beijing Advanced Innovation Center for Future Urban Design, Beijing University of Civil Engineering and Architecture (No. UDC2019032824)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The soil nail head is the weak point in the overall structure of the soil nail wall. In order to study the anchorage performance of soil nail head, this paper takes an assembled flexible surface GFRP reinforced soil nail wall as an example. Through indoor nail head anchorage performance test and 3D numerical simulation the ultimate tensile strength, nail head deformation and damage pattern of hollow GFRP bar nail head with 32 mm outer diameter were investigated. It was found that the ultimate load bearing capacity of such GFRP bar nail head is between 240 kN and 290 kN. When the nut is tightened, the stress of the thread is mainly distributed in the first three rings of threaded teeth, with significant stress concentration exists at the first ring of threaded teeth in the head of the nail. In addition, a mechanical model of the threaded tooth of the nail head was developed using the thread expansion method, and the relationship between the ultimate shear strength of the first ring thread and the ultimate load on the nail head was derived. The ultimate load-carrying capacity of this GFRP bar nail head was calculated to be 244.54 kN, which is consistent with the test results.The brittle damage characteristics of the indoor nail head anchorage performance test determined that the safety factor of GFRP tendon nail head is between 1.8 and 2.0. It is also determined that the safe load of such GFRP tendons is between 125 kN and 135 kN, providing a reference for the research and application of similar projects.

    Reference
    Related
    Cited by
Get Citation

刘军,宋晔,张建全,牛大伟.GFRP筋土钉支护钉头的锚固性能[J].土木与环境工程学报(中英文),2024,46(3):94~102

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 08,2022
  • Revised:
  • Adopted:
  • Online: May 20,2024
  • Published:
Article QR Code