Experimental study on performance deterioration and pore structure development law of aerated concrete under negative temperature curing
CSTR:
Author:
Affiliation:

1.School of Civil Engineering, Lanzhou Jiaotong University, Lanzhou 730070, P. R. China;2.Key Laboratory of Road & Bridges and Underground Engineering of Gansu Province, Lanzhou Jiaotong University, Lanzhou 730070, P. R. China

Clc Number:

TU528.31

Fund Project:

Scholars and Innovation Team Development Program (No. IRT_15R29); National Natural Science Foundation of China (No. 51768033); University Collaborative Innovation Science and Technology Team Support Program of Gansu Province (No. 2017C-08); Longyuan Youth Innovative Talents (Team) Project; Scientific Research Project of Higher Education Institutions of Gansu Province (No. 2018B-054)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In this experiment, by comparing the compressive strength values and internal pore structure of five different aerated concrete test blocks at different ages under the conditions of negative temperature curing and standard curing, the development law of the compressive strength of aerated concrete is analyzed based on the (-5 ℃) curing condition, and the range of less harmful pores under this condition is further clarified based on the relationship between the pore size and the pore water; and the inherent lack of strength of aerated concrete is analyzed from a microscopic point of view. The experimental results show that the continuous (-5 ℃) curing has an obvious restraining effect on the growth of the compressive strength of aerated concrete, and the strength is less than the standard curing test block at the same content; under the same curing conditions, the strength and content are affected by the air-entraining agent. There is a negative correlation between them; based on the negative temperature curing environment, the high content of aerated concrete will reduce the compactness of the concrete due to the increase in the number of pores in the slurry, which will affect the compressive strength of the concrete to a certain extent, but it will cause the resistance of the aerosol to the negative temperature environment cannot be ignored. In order to analyze the balance between the negative temperature environment and the amount of air-entraining agent, the pore structure development law and strength growth system of cement-based materials under negative temperature are used to ensure that the compression the strength of aerated concrete is low and the pore structure is relatively optimized. Under the premise of finding the content of aerated concrete under the condition of negative temperature (-5 ℃).

    Reference
    Related
    Cited by
Get Citation

张戎令,于博,郭海贞.持续负温(-5 ℃)养护条件下含气混凝土性能劣化及孔结构发展规律试验研究[J].土木与环境工程学报(中英文),2024,46(3):180~188

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 29,2021
  • Revised:
  • Adopted:
  • Online: May 20,2024
  • Published:
Article QR Code