Inner temperature field numerical analysis of reinforced-soil retaining wall under significant temperature fluctuation
DOI:
Author:
Affiliation:

1.School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology;2.Xinjiang Institute of Architectural Sciences (Limited Liability Company);3.School of Civil and Transportation Engineering, Hebei University of Technology

Clc Number:

Fund Project:

CSCEC Xinjiang Construction and Engineering Group Co., LTD (No. 65000022859700210197)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To investiage the changing regularity of temperature field of geogrid-reinforced soil (GRS) retaining wall under the significant temperature fluctuation, this study focused on a GRS retaining wall in Urumqi as the engineering context. Finite element models were constructed and employed to analyze the inner temperature distribution characteristics of the GRS retaining wall, taking into account the influence of solar radiation. The findings indicate a strong correlation between the inner temperature field of the GRS retaining wall and variations in environmental temperature, with the isotherm closely resembling a hyperbolic shape. Specifically, the temperature field within approximately 3-4.0 m behind the facing panels and about 2.0 m below the top surface of the GRS retaining wall can be classified as temperature-sensitive regions. Furthermore, the width of these temperature-sensitive regions expands in proportion to the thermophysical parameters. The utilization of filling material possessing enhanced thermophysical properties can effectively alleviate the average temperature gradient ?TV, however, the magnitude of the average temperature gradient ?TV predominantly depends on the rate of fluctuation in the external temperature. The maximum depths of frost exhibit an increase with the saturation of filling materials, with the most significant increment observed during the transition from a saturation level of 0 to 0.2. Furthermore, the findings of this study will serve as a significant point of reference for future investigations into the enduring stability of GRS retaining walls.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 28,2023
  • Revised:December 08,2023
  • Adopted:December 26,2023
  • Online:
  • Published:
Article QR Code