    In this paper, the temperature field, stress, critical crack size and expenditure rate of life of HP and IP rotors of 200MW Chinese-built steam turbines in eight typital patterns of cold start of Chongqing Power Plant was calculated by finite element method. Some problems in speed-up process have been discussed, and advanced that it is better to appraise start-up process by Fracture Mechanics Mechod in the period when the temperature of rotor is low. The discussion are useful for the start of steam turbines.

    Reference
    Related
    Cited by
Get Citation

陈锋 王蔼人.国产200MW汽轮机冷态启动的研究[J].重庆大学学报,1991,14(5):69~73