Test & Analysis of Moment-Torque Distribution Between Spandrel Beams And Beams of Floor System With P.C. Long-span Beams
CSTR:
Author:
Affiliation:

Clc Number:

TU378 TU231

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The test of four large scale specimens of floor system with P.C. long-span beams is introduced.The restraining torsional moment of spandrel beams caused by P.C. beams with or without slab is focused on,along with change of the load-torque relationship affected by the beams' bending rigidity and the spandrel beams' torsional rigidity under different load level. The result presents important reference to the revision of national design standard and structural design.

    Reference
    Related
    Cited by
Get Citation

黄音,周峥,王正霖.大距度预应力次梁楼盖边梁、次梁弯扭分配试验[J].重庆大学学报,2001,24(3):53~57