Experimental Investigation of Passive Emergency Core Cooling System
Article
Figures
Metrics
Preview PDF
Reference
Related
Cited by
Materials
Abstract:
The effect of different break size at cold leg , different pressure balance line and automatic depressurize system on transient behavior of passive emergency core cooling system was investigated on the AC600CMT test facility. The experiment process and experiment results were described.