Seismic Performance Analysis and Optimum Design of RC Frame Structure Retrofitted by Viscidity Dampers
CSTR:
Author:
Affiliation:

Clc Number:

TU352.1

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    For a reinforce concrete frame structures which is not satisfied the standard for seismic appraiser of building, viscidity dampers are used to retrofit the structure. Four reinforce schemes are selected in which six same viscidity dampers are located at different position of the structure. Compared seismic performance of the retrofited structure with unretrofited one, an optimum scheme where viscidity dampers should better set is obtained. Then the number and technical parameter of viscidity dampers are adjusted, and seismic performance of the structure are calculated. The results are compared and a more economic scheme is obtained because the cost is lowest and the displacement of the structure under earthquakes is satisfied the standard for seismic appraiser of building. Several rules and advices are gotten about how to use the viscidity dampers to retrofit reinforce concrete frame structures. The conclusion about viscidity dampers are useful for similar actual engineering.

    Reference
    Related
    Cited by
Get Citation

杨溥,姬淑艳,肖志,李英民.粘滞阻尼器加固的某RC框架结构抗震性能分析及优化设计[J].重庆大学学报,2007,30(8):114~118

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:March 30,2007
  • Adopted:
  • Online:
  • Published:
Article QR Code