Seismic Performance Analysis and Optimum Design of RC Frame Structure Retrofitted by Viscidity Dampers
Article
Figures
Metrics
Preview PDF
Reference
Related
Cited by
Materials
Abstract:
For a reinforce concrete frame structures which is not satisfied the standard for seismic appraiser of building, viscidity dampers are used to retrofit the structure. Four reinforce schemes are selected in which six same viscidity dampers are located at different position of the structure. Compared seismic performance of the retrofited structure with unretrofited one, an optimum scheme where viscidity dampers should better set is obtained. Then the number and technical parameter of viscidity dampers are adjusted, and seismic performance of the structure are calculated. The results are compared and a more economic scheme is obtained because the cost is lowest and the displacement of the structure under earthquakes is satisfied the standard for seismic appraiser of building. Several rules and advices are gotten about how to use the viscidity dampers to retrofit reinforce concrete frame structures. The conclusion about viscidity dampers are useful for similar actual engineering.