Development of a sub-nanosecond steep pulse generatorfor simulating weak PD UHF signal
CSTR:
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    In need of ultra-high frequency partial discharge location and correction of electrical equipment, we designed a sub-nanosecond steep pulse generator, and constructed the corresponding circuit model through the circuit simulation software Pspice. The influence of the storage capacitor and the supply voltage to the pulse waveform is analyzed. When the storage capacitor is 10 pF and 20pF respectively, the output pulse waveforms have been measured in the conditions of pulse rise time being 0.68 ns and 0.90 ns, pulse width being 0.98 ns and 1.18 ns, pulse peek being 8.72 V and 12.2 V respectively, and partical discharge capacity of charge being 320 pC and 600 pC. The picked multi-pulse singnals are steady with the developped sleeve monopole antenna, the error is less than 70 ps. It can be used for the experimental study of ultra-high frequency partial discharge location and correction of electrical equipment.

    Reference
    Related
    Cited by
Get Citation

唐炬,麻守孝,张晓星,许中荣.模拟微弱PD UHF信号纳秒级陡脉冲源的研制[J].重庆大学学报,2010,33(7):23~28

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 10,2010
Article QR Code