The GPS-X simulation of a waste water treatment plant based on the characterization of COD
CSTR:
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    The mechanism and the modeling process of the activated sludge system simulation software GPS-X are described, and combined with the results of characterization of COD components, an instance of the software’s application in a sewage treatment plants is analyzed. The simulation results present the COD with a maximum error of 5.48%, a minimum error of 0.83%, and an average relative error of 2.85%, TN with a maximum error of 7.23%, a minimum error of 0.15%, and an average relative error of 3.62%, and NH+4-N with a maximum error of 9.17%, a minimum error of 1.05%, and an average relative error of 4.98%. The simulation results match the measured results and reflect the actual situation of sewage treatment plants preferably.

    Reference
    Related
    Cited by
Get Citation

艾海男,何强,张代钧,许丹宇,汪林.基于COD组分表征的GPS-X对污水厂的模拟[J].重庆大学学报,2011,34(5):82~86

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 21,2011
Article QR Code