Study on constant current control of inductive power transfer with parameter identification
CSTR:
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    Aiminy at magnetic exciting current (resonant current) control, a constant current control method based on dynamic parameter identification is put forward. With energy conversion analysis, the energy storage, supply and dissipation functions of the system resonant network are constructed. The reflecting impedance identification functions are obtained by constructing the energy equilibrium relations in a period and among several periods. Furthermore, a constant current control strategy by regulating the system input voltage with Buck converter is presented. Combining the relations among system input voltage, the envelope of resonant current and the input of Buck converter, the constant current control law is proposed. The control law is verified with experiments. For the proposed method, in parameter identification, only the data of zero crossing point of resonant voltage and current are required, which reduces the complexity and costs of sampling system. Also, the constant current control law does not need complex computation and is easy to implement.

    Reference
    Related
    Cited by
Get Citation

戴欣,孙跃,苏玉刚,王智慧,唐春森.感应电能传输系统参数辨识与恒流控制[J].重庆大学学报,2011,34(6):98~104

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 20,2010
Article QR Code