The equivalent enthalpy drop theory calculation of the ejector heaters applied for low-pressure feed water heater system of thermal power unit
CSTR:
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    There is much exergy loss in low-pressure feed water heater system of the thermal unit. The thermo-economic characters by the equivalent enthalpy drop method while the low-pressure heater was replaced with the ejector heater. At the same time, the thermo-economic characters formulas for the different factors were also gotten. Based on these results, the thermo-economic changing features were analyzed for the low pressure heaters replaced with the ejector heaters of the N600-165/535/535 units, and the results were compared with the normal heat balance method. The results show that the ejector heaters can reduce the exergy loss efficiently, and the thermo-economic effects is the best for replacing the all low-pressure heaters with the ejector heaters, and its efficiency can be increased by 0.263%. The given equations of this paper can be used for analyzing the thermal economic effects.

    Reference
    Related
    Cited by
Get Citation

杨琳,冉景煜.引射式加热器替代低压回热系统等效焓降分析[J].重庆大学学报,2011,34(10):76~81