Poly-generation of cooling, heating and power performance analysis of PV radiant panel PV/T system
CSTR:
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    A combined cooling, heating and power mono-silicon solar photovoltaic radiant panel (PV/R) is proposed, which compounds the radiant panel with the PV module. The PV operating temperature is decreased through the internal cycling of liquid pipe of radiant panel. Thus the power efficiency of PV module is increased, at the same time, the heat of PV using for heating can be recollected. While at night, the cooling used for the daytime is collected through the nocturnal cooling storage. In the experiment testing, the PV/R not only increases the power efficiency by 8%~16%, but obtains the heating efficiency by 45% and gets the cooling capacity of 40~80 W/m 2.

    Reference
    Related
    Cited by
Get Citation

尹宝泉,王一平,朱丽,崔勇,黄群武.光伏辐射板型PV/T系统的电热冷性能[J].重庆大学学报,2013,36(10):114~119

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Online: October 29,2013
Article QR Code