Comparison of application effects of water-side and air-side economizers in a data center
DOI:
CSTR:
Author:
Affiliation:

School of Civil Engineering Chongqing University

Clc Number:

TU831 ???????????

Fund Project:

The project was supported by the National Natural Science Foundation of China (No.51778080).),Chongqing Technology Innovation and Application Development(cstc2020jscx-msxmX0184)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    While data centers consume a lot of energy, the consumption of water resources cannot be ignored. Air-side economizer, an effective energy-saving technology for data centers, is constrained by outdoor air pollutants. Based on the actual energy consumption, water consumption and air conditioning test data of a data center, taking into account the indoor environmental requirements and the outdoor air pollutant conditions of the data center, the feasibility of applying the air-side economizer was discussed and its calculation method of energy and water consumption was analyzed, and the calculation results were compared with the actual application of the water-side economizer. The results show: The data center has a Power Usage Effectiveness (PUE) of 1.56 and a Mechanical Load Component (MLC) of 0.43 under mechanical cooling and significant energy savings under full free cooling in the water-side economizer, with a PUE of 1.40 and MLC of 0.25. Compared with the period of applying water-side economizer, the PUE of applying air-side economizer is 1.27, MLC is 0.13, the average daily water consumption is about 30% of the cooling tower water consumption, and the Water Use Efficiency (WUE) is 1.01, so the energy and water saving potential is much higher than that of water-side economizer. In addition, the water-saving performance of the air-side economizer will be further improved as the specification requirements for the lower limit of humidity in the data room environment are reduced. This provides a basis for subsequent research on the combination of air-side and water-side economizers , as well as for proposing the idea of " air-side prioritization, water-side supplementation".

    Reference
    Related
    Cited by
Get Citation
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 13,2022
  • Revised:August 18,2023
  • Adopted:April 12,2024
  • Online:
  • Published:
Article QR Code