含旋转振子的周期基础对地震弯曲波的隔震作用
CSTR:
作者:
作者单位:

北京林业大学 水土保持学院,北京 100083

作者简介:

LIU Guanchen (1993- ), main research interest: periodic structure isolation, E-mail: yang67896@163.com.

通讯作者:

HUANG Jiankun (corresponding author), PhD, associate professor, doctorial supervisor, E-mail: jiankunhuang@bjfu.edu.cn.

中图分类号:

TU352.12

基金项目:


Bending wave isolation by periodic foundation with rotational oscillators
Author:
Affiliation:

School of Soil and Water Conservation, Beijing Forestry University, Beijing 100083, P. R. China

Fund Project:

National Natural Science Foundation of China (No. 31700637, 32071841)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    提出一种含旋转振子的周期性基础(PF)板,用于高层建筑对地震弯曲波的隔震。早期对PF隔震的研究主要针对平面波,但地震波对于周期性基础板结构更易激发弯曲波。突破以往研究仅针对平面波的局限性,对弯曲波输入的频散关系进行探究;通过有限元法,利用可考虑板厚影响的SHELL单元计算PF板的弯曲波衰减域,系统研究材料参数和几何参数对弯曲波衰减域的影响;通过对三维有限元模型进行弯曲波和地震波入射的数值仿真试验,验证PF隔震的有效性。结果表明:弯曲波衰减域对连杆的宽度和弹性模量变化很敏感;在弯曲波输入下,PF的衰减域在10 Hz以下,与混凝土基础板相比,PF对弯曲波的隔震效率大于60%,能够作为高层建筑的隔震基础。

    Abstract:

    A periodic foundation (PF) plate with rotational oscillators was used for the bending wave isolation of high-rise buildings. Previous studies concerning the PF focused on the in-plane waves. However, seismic waves easily excite bending waves for the periodic foundation plate structure. This study broke through the limitation of plane wave research by studying the bending wave dispersion curves. The finite element method was employed to calculate the bending wave Attenuation Zones (AZs) of the PF plate by the SHELL element which can consider the influence of the plate thickness of the plate. The influences of the material and geometrical parameters on the bending wave AZs were comprehensively investigated. The effectiveness of the PF was demonstrated via a three-dimensional finite element model under incident harmonic bending-waves and seismic waves. The results show that the bending wave AZs are sensitive to the width and elastic modulus of the linkers. The bending wave AZs of the PFs were lower than 10 Hz, and the seismic isolation efficiency was greater than 60% compared to the concrete foundation, which is sufficient for it to serve as a seismic isolation foundation for high-rise buildings.

    参考文献
    相似文献
    引证文献
引用本文

刘冠辰,张之伟,黄建坤,胡雨村.含旋转振子的周期基础对地震弯曲波的隔震作用[J].土木与环境工程学报(中英文),2023,45(5):66-80. LIU Guanchen, ZHANG Zhiwei, HUANG Jiankun, HU Yucun. Bending wave isolation by periodic foundation with rotational oscillators[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,2023,45(5):66-80.10.11835/j. issn.2096-6717.2021.245

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-06-18
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-08-24
  • 出版日期:
文章二维码