无回流间歇曝气系统总磷去除的实验分析
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

X703

基金项目:


Analysis of Phosphorus Removal in the Non-backflow Intermittent Aeration System
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    对无回流间歇曝气系统工况,泥龄与总磷去除率关系进行了探索,通过单因素和双因素正交试验,找出了工况,泥龄共同影响下的ηTP。试验表明,在曝气停曝周期T=6.0h,厌氧时间1.5h,沉淀排水时间0.5h的条件下,当SRT=20d,曝气比为0.42时NBIAS系统的ηCODcr,ηIN,ηTP分别为85%,75%,69%。

    Abstract:

    In this paper the phosphorus removal performance has been studied in Non-backflow Intermittent Aeration System (NBIAS), when the aeration duration and SRT were adjusted. At the same time, nitrogen removal was also studied. Test results show that when the cycle duration is 6 h., anaerobic duration 1.5h. sedimentation and displacement time 0.5 h. and SRT=20 d,aerobic ratio 0.42, the removal efficiency for CODcr, nitrogen and phosphorus will be 85%, 75% and 69%, respectively.

    参考文献
    相似文献
    引证文献
引用本文

罗固源 刘智刚.无回流间歇曝气系统总磷去除的实验分析[J].土木与环境工程学报(中英文),1999,21(6):56-. LOU Gu_yuan LIU Zhi_gang. Analysis of Phosphorus Removal in the Non-backflow Intermittent Aeration System[J]. JOURNAL OF CIVIL AND ENVIRONMENTAL ENGINEERING,1999,21(6):56-.10.11835/j. issn.1674-4764.1999.06.014

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期: