Abstract:SIMPLE method is used to study the influence of aspect ratio on the natural convection in an enclosure with five discrete heat sources on a vertical wall and an isothermal heat sink on another vertical wall. The range of aspect ratio is from 3. 0 to 12. 22. At high aspect ratio, multiple secondary flow cells can be found,which enhance heat transfer strongly and cause the highest heat transfer coefficient based on cooling area Nuc. With the decrease of aspect ratio,secondary flow cells become weaker gradually and finally reach the lowest Nuc at H/W = 7. 35. If H/W continues to decrease,natural convection is gradually developed,and heat transfer is improved. At H/W = 3. 67,Nuc becomes stable. Then the decrease of aspect ratio will not affect heat transfer. Besides, A heat transfer correlation including the influence of aspect ratio is .also provided.