Abstract:A theoretical analysis of the Resonant DC Base High Frequency Inverter is given. A optimal control scheme for the short circuit current of the resonant inductor is proposed. The system parameters,output current,output voltage and characteristics of the Resonant DC Base in this scheme are analysed. In the theoretical analysis the load is supposed as a resistor to void the calculating error while the load is treated as a constant current source. The analysis and test result have proved that the optimal parameters of the Resonant DC are only determined by the load resistance and the output frequency.