Abstract:In the established model, the cooling differences are considered between the surface of inner radius and that of outer radius, and in the transverse direction of thin slab. And the conception for the effective coefficient of spraying water in continuous casting is firstly put forward. According to different casting speeds and different cooling zones, different time step lengths are adopted. In this model the heat transfer differences are thought over among vertical and curved zones, wide and narrow surfaces an well as angular zone of mould. The method of the corrected equivalent specific heat is used to deal with latent heat. The influence of forced convection is considered on heat transfer. Therefore, the model has higher accuracy and is consistent with the practice.