Abstract:A fuzzy neural network diagnosis model is established on the basis of the vibration failure features of steam turbine-gernerator set, two kinds of fuzzy inputing method are discussed. At last, the performance of the fuzzy neural network is compared with that of the conventional BP network. The results show that the method presented is suitable for identifying the vibration failure of steam turbine-gernerator set, and it is more efficient in deal with the uncertain data than BP network diagnosis.