[关键词]
[摘要]
气体绝缘组合电器(GIS)的同轴结构有利于局部放电激发的电磁场传播,为内部传感器检测局部放电提供了有利的条件,针对GIS结构及其中局部放电的特点,设计了用于局放信号检测的圆板型和圆环型两种内置电容耦合式传感器,描述了该传感器的结构。通过方波响应试验仿真与试验实测研究了传感器频率响应特性,并采用方波信号输入输出关系曲线分析了传感器对暂态信号搞合的输入输出特性。用所设计的传感器进行GIS模拟装置中电晕放电脉冲实测,实测结果表明设计的传感器性能可靠,灵敏度较高,可用于GIS局部放电的测量。
[Key word]
[Abstract]
The coaxial configuration of gas-insulated substations is of great advantages transmitting the electromagnetic wave excitated by partial discharge and of great advantages of partial discharge detection. Based the characteristics of configuration of GIS and PD signals inside, the authors design a disc coupler and a loop coupler for continuous monitoring of partial discharge in GIS, and analyze the sensor's characteristics theoretically. The frequency response (FR) characteristics of the disc coupler and the loop coupler are analyzed by the simulation and measurement realistically of square wave response. In addition, the measured results of partial discharge by the sensors designed in GIS are given, and it is shown that the sensors designed are available for the measurement of partial discharge in GIS.
[中图分类号]
TM855 TP212.1
[基金项目]
重庆市应用基础基金资助项目 ( 2 0 0 2 -4 5 )